IT-M3800 Regenerative DC electronic load
  • IT-M3800 Regenerative DC electronic load
  • IT-M3800 Regenerative DC electronic load
  • IT-M3800 Regenerative DC electronic load
  • IT-M3800 Regenerative DC electronic load
  • IT-M3800 Regenerative DC electronic load

IT-M3800 Regenerative DC electronic load

IT-M3800

IT-M3800 series regenerative DC electronic load can not only perform as a DC load, but also feed back power to the grid, which saves electricity and cooling costs for you. It can complete high-precision output and measurement, and supports multiple protection functions. It is well applied to the test of 5G communication and data center, industrial components test, aging test, PV and energy storage test, power optimizer and other fields.

Model
Description

Product Features
  • Compact design, 1U@6kW, 2U@12kW
  • Voltage range:10~1500V
  • Current range: 8A~720A
  • Power range: 12kW
  • Master/slave parallel connection with parallel technology - keep good performance while power extension*1
  • Efficient power regeneration -  reduce cost of electricity and cooling 
  • Slope of voltage, current and power is settable
  • Battery discharge test
  • Short-circuit simulation 
  • List function, max.200 steps 
  • 8 operation modes under Source mode: CC/CV/CW/CP/CC+CV/CV+CR/CR+CC/CC+CV+CW+CR
  • Von function - On/Off control
  • Multiple protection: OVP / ±OCP / ±OPP / OTP /voltage transient drop protection/anti-islanding
  • Power grid automatic detection
  • Pre-charge to prevent current overshoot
  • Built-in USB/CAN/LAN/digital IO interfaces, Optional GPIB/Analog&RS232

* If parallel connection > 6 units, pls. contact ITECH for details.

 

Functions and Advantages

 

High power density, compact size design

ITECH has been adhering to the high power density design to help customers optimize test solutions. IT-M3800 series provide up to 6kW power in 1U chassis, and up to 12kW power in 2U chassis. ITECH entire high power density product line is more complete and comprehensive.

IT-M3800

 

Wide range design, save your purchasing cost

The IT-M3800 series has 25 models, with voltage from 10V~1500V and current up to 720 A. The wide range design provides users with more voltage and current combinations than the traditional fixed range DC loads, making it more flexible. A single unit can cover a wide range of applications, significantly reducing the complexity of system building and saving room.

IT-M3800

 

Power regenerative and eco-friendly

With the power regeneration function, IT-M3800 can feed back up to 95% power instead of consuming it as heat. It not only save your cost of electricity, HVAC and cooling infrastructure, but also help to reduce carbon emission and impact on the environment. In addition, IT-M3800 has the function of automatic grid detection, which can detect phase voltage and frequency in real time and synchronizes with the grid to make energy regeneration automatic and safe.

IT-M3800

 

Electricity accumulation, high energy saving effect

IT-M3800 uses power electronic conversion technology to recycle the output energy of the power supply under test under the premise of completing the test power experiment. Through the internal high-speed voltage and current sampling, the user can directly view the current total amount of feedback on the instrument panel, including voltage/frequency/power of each phase. The total power, real time and historical total recovered electricity. The IT-M3800 series can continue to accumulate electricity on the basis of the value before the last shutdown.

 

Battery discharge test

The IT-M3800 series have discharge test function, which is suitable for discharging tests on various portable batteries. Three test cut-off conditions of the battery can be set by yourself: cut-off voltage, cut-off capacity and discharge time. When any one of the three conditions is met, the test will be automatically interrupted. During the test, the battery voltage, discharge time and discharged capacity can be observed.

 

Parallel function

To be convenient and flexible, IT-M3800 uses the master/slave control mode to connect multiple e-loads in parallel to realize high-power testing requirements. Meanwhile, it adopts ITECH's optical fiber parallel technology to solve the problems of slow speed and poor accuracy in the traditional parallel mode, suitable for calibration measurement, research and development lab, production line and ATE test setup.

Product Details
IT-M3800

Data sheet

Current type
DC
Range
1.7 ~ 12kW, 8000A
Type of product
Regenerative el. load
Attachments
Download
IT-M3800 Datasheet, EN

IT-M3800 Series Datasheet, English

Download (1.23MB)

IT-M3800 Series. Models

  

All models interface: USB/CAN/LAN/digital I/O port, optional GPIB/analog & RS232

Model Voltage Current Power Resolution Accuracy Size
IT-M3802-300-20 300V 20A 2kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3812-80-240 80V 240A 12kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3806-80-120 80V 120A 6kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3804-80-80 80V 80A 4kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3802-80-40 80V 40A 2kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3812-32-480 32V 480A 12kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3806-32-240 32V 240A 6kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3804-32-160 32V 160A 4kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3802-32-80 32V 80A 2kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3807-10-720 10V 12~720A 120~7200W 0.001V/0.1A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3803-10-360 10V 6~360A 60~3600W 0.001V/0.1A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3802-10-240 10V 4~240A 40~2400W 0.001V/0.1A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3801-10-120 10V 3~120A 12~1200W 0.001V/0.1A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3812-1500-24 1500V 24A 12kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3806-1500-12 1500V 12A 6kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3812-800-48 800V 48A 12kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3806-800-24 800V 24A 6kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3804-800-16 800V 16A 4kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3802-800-8 800V 8A 2kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3812-500-72 500V 72A 12kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3806-500-36 500V 36A 6kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3804-500-24 500V 24A 4kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3802-500-12 500V 12A 2kW 0.01V/0.001A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3812-300-120 300V 120A 12kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 2U
IT-M3806-300-60 300V 60A 6kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U
IT-M3804-300-40 300V 40A 4kW 0.001V/0.01A ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS 1U

  

All models interface: USB/CAN/LAN/digital I/O port, optional GPIB/analog & RS232

Subject to change without notice

Comments (0)
Grade
No customer reviews for the moment.
2 other products in the same category:

Reference: IT-M3600

Brand: ITECH Electronic

IT-M3600 Regenerative Power System (200 ~ 800W)

(0)
IT-M3600 regenerative power system integrates two instruments in one, which is a bidirectional power supply and a regenerative electronic load. When used as a load, its energy recovery function can convert the absorbed DC power into AC power and return it to the grid. When used as a power supply, it can also be used as a wide range bidirectional DC power...

Reference: IT8245-350-270

Brand: ITECH Electronic

IT8200 Regenerative AC/DC Electronic Load

(0)
IT8200 Series is a regenerative programmable AC/DC electronic load. It is power regenerative, which not only saves electricity and cooling costs for you, but also good for energy saving and environmental protection. AC load mode supports both rectification and non-rectification, providing CC/CR/CP/CS/CC+CR/CE operating modes. It can simulate multiple...