Reference: IT7800
Brand: ITECH Electronic
IT-M3900B regenerative power system feature two-in-one, which could use as a bidirectional DC power supply, also act as an independent regenerative load.
One-button-switch between source and load mode, a unique and decisive feature for the user groups that works in different applications such as battery, PV energy storage, electric vehicle, Green energy and some ATE fields.
Product Features
Multiple protection:
*1. If parallel connection >6 units, pls. contact ITECH for details
*2. Not available for 10V models
One button switch, bidirectional power & Regenerative load
Different from other bidirectional power supplies, IT-M3900B series is a regenerative power system which combines two devices into a 1U unit. It is both a bidirectional DC power supply and also a regenerative DC electronic load. You can switch between Source and Load with one button on the front panel.IT-M3900B not only saves space and equipment purchasing cost for you, but also enables you to connect DUT easily. It can switch seamlessly between source and sink mode fast and continuously, which avoids voltage or current overshoot effectively. IT-M3900B can be well applied to battery test, cell packaging equipment test, battery protection board test, etc.
Battery simulation function
IT-M3900B unique bidirectional design and variable output impedence makes it easy for the users to set voltage/capacity/internal resistance/SOC quickly to define battery matrix quickly from the front panel, to simulate the charge/discharge characteristics of battery and assist with other tests. ITECH provides optional BSS2000 battery simulation software, then users can self-define the battery curve by setting common parameters, also can set battery initial capacity to verify the DUT characteristics under different battery status. Meanwhile, BSS2000 supports importing matlab battery matrix or CSV. file with battery charging and discharging curve, so as to simulate real battery charge and discharge characteristics.
With optional ITS5300 battery testing software, it can do the below testing items:
Data sheet
All models interface: USB/CAN/LAN/digital I/O port, optional GPIB/analog & RS232
Model | Voltage | Current | Power | Resolution | Accuracy | Size |
IT-M3902B-80-40 | 80V | ±40A | ±2kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3912B-32-480 | 32V | ±480A | ±12kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3906B-32-240 | 32V | ±240A | ±6kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3904B-32-160 | 32V | ±160A | ±4kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3902B-32-80 | 32V | ±8A | ±24kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3910B-10-1020 | 10V | -720 ~ 1020A | -7200 ~ 10200W | 0.001V/0.1A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3905B-10-510 | 10V | -360 ~ 510A | -3600 ~ 5100W | 0.001V/0.1A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3903B-10-340 | 10V | -240 ~ 340A | -2400 ~ 3400W | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3901B-10-170 | 10V | -120 ~ 170A | -1200 ~ 1700W | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3904B-800-16 | 800V | ±16A | ±4kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3902B-800-8 | 800V | ±8A | ±2kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3912B-500-72 | 500V | ±72A | ±12kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3906B-500-36 | 500V | ±36A | ±6kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3904B-500-24 | 500V | ±24A | ±4kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3902B-500-12 | 500V | ±12A | ±2kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3912B-300-120 | 300V | ±120A | ±12kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3906B-300-60 | 300V | ±60A | ±6kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3904B-300-40 | 300V | ±40A | ±4kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3902B-300-20 | 300V | ±20A | ±2kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3912B-80-240 | 80V | ±240A | ±12kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3906B-80-120 | 80V | ±120A | ±6kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3904B-80-80 | 80V | ±80A | ±4kW | 0.001V/0.01A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3912B-1500-24 | 1500V | ±24A | ±12kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3906B-1500-12 | 1500V | ±12A | ±6kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
IT-M3912B-800-48 | 800V | ±48A | ±12kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 2U |
IT-M3906B-800-24 | 800V | ±24A | ±6kW | 0.01V/0.001A | ≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS | 1U |
All models interface: USB/CAN/LAN/digital I/O port, optional GPIB/analog & RS232
Subject to change without notice
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: IT7800
Brand: ITECH Electronic
Reference: IT-M7723
Brand: ITECH Electronic
Reference: IT6000B
Brand: ITECH Electronic
Reference: IT-M3900C
Brand: ITECH Electronic
Reference: IT6300
Brand: ITECH Electronic
Reference: IT-M3400
Brand: ITECH Electronic
Reference: IT-M3100
Brand: ITECH Electronic
Reference: IT7300
Brand: ITECH Electronic
Reference: IT6000C
Brand: ITECH Electronic
Reference: IT7626
Brand: ITECH Electronic
Reference: IT-M3600
Brand: ITECH Electronic
Reference: IT-N6900
Brand: ITECH Electronic
Reference: IT7900P
Brand: ITECH Electronic
Reference: IT6600C
Brand: ITECH Electronic
Reference: IT2700
Brand: ITECH Electronic
Reference: IT7900
Brand: ITECH Electronic
check_circle
check_circle