EFD-1891 FieldMan E-Field probe, 2MHz - 18GHz
  • EFD-1891 FieldMan E-Field probe, 2MHz - 18GHz

EFD-6091 FieldMan E-Field probe, 100MHz - 60GHz

EFD-6091

Isotropic measurement of electric fields from 100 MHz to 60 GHz using the Field Meter FieldMan®

Kuvaus

The probe detects electric fields from 100 MHz up to 60 GHz. This frequency range covers almost the entire range of high frequency communications, right up to directional radio and satellite links and is also suitable for measurements on radar systems. The probe’s high linearity and sensitivity make it ideal for checking human safety limit values in the general public and occupational environments.

The probe's interface digitally transmits the measurement data to the base unit, which has no individual influence on the measured values and therefore does not need to be calibrated. Probe calibration is carried out at several frequencies. The calibration data is stored in the probe and is automatically taken into account during the measurement. If the frequency of the predominating field strength is known, a correction factor can additionally be applied to increase the measurement accuracy.

  • Isotropic (non-directional) measurement
  • Excellent sensitivity starting at 0.5 V/m
  • Wide True RMS range up to 61 V/m
  • Digital probe interface - no more meter calibration
  • Self-test of the probe interface with integrated sensor function test
  • Automatic offset correction, no zero adjustment required
  • Wide temperature range from -20 °C to +50 °C
  • Extremely low temperature response
  • High Immunity at 50/60 Hz
  • Calibration is performed up to 60 GHz and is accredited up to 18 GHz
Tuotetiedot
EFD-6091

Lisätiedot

Kenttä
Sähkökenttä
Mitat
308 mm x 66 mm Ø
Paino
up to 100 g
Taajuusalue
100MHz to 60GHz
Käyttöolosuhtee
-20 °C to +50 °C
up to 29 g/m³ (up to 93 % RH at +30 °C), non-condensing
Suojausluokka
IP54 (probe screwed on)
Tuotteen tyyppi
FieldMan probes
Dynaaminen alue (dB)
58
Mittausalue, E-kenttä
0.5 to 61.4 V/m (True RMS), 66 nW/cm² to 1.0 mW/cm² (True RMS)
0.5 to 400 V/m (CW), 66 nW/cm² to 42 mW/cm² (CW)
Type of frequency response
Flat
Jatkuva aaltovauriotaso
1600 V/m, 700 mW/cm²
Huippuvaurio
1900 V/m, 1 W/cm²
Anturin tyyppi
Diode based system
Suuntaus
Isotrooppinen (kolmiakselinen)
Tila-arviointi
Combined 3-axis (RSS)
Näytteenottotaajuus
5 Hz / 275 ms
Lämpötila-anturit
Integrated sensors for displaying the ambient temperature, for automatic offset compensation and for compensation of the temperature response
Itsetestaus
Interface function test and sensor test for interruption of diodes
Taajuusvasteen tasaisuus
+3/-6 dB (100 MHz to 60 GHz)
±3 dB (300 MHz to 40 GHz)
Lineaarisuuden poikkeama
±1 dB (1 μW/cm² to 16.5 mW/cm²)
±1 dB (2 to 250 V/m)
±2 dB (16.5 mW/cm² to 42 mW/cm²)
±2 dB (250 to 400 V/m)
±3 dB (0.26 to 1 μW/cm²)
±3 dB (1 to 2 V/m)
Isotrooppinen poikkeama
±1.25 dB (100 MHz to 10 GHz)
±2 dB (more than 10 GHz to 26.5 GHz)
±2 dB typ. (more than 26.5 GHz)
Lämpötilavaste
±0.2 dB (-20 °C to +50 °C, related to 23 °C)
Akkreditoitu kalibrointi
DAkkS, ILAC-MRA (DIN EN ISO/IEC 17025, IEEE Std. 1309)
For measurands outside the scope, a factory calibration is performed.
Suositeltu kalibrointiväli
24 kuukautta
Liitteet
Lataa
FieldMan Brochure

FieldMan Brochure, v. NSTS 03/23 E0384B, English

Lataa (6.51MB)
Datasheet Probe EFD-6091

Datasheet Probe EFD-6091, v. NSTS 0623-E0391A, English

Lataa (309.08KB)
Kommentit (0)
Arvosana
Tällä hetkellä ei ole asiakkaiden arvosteluja.
10 muuta tuotetta samassa kategoriassa:
Saatat pitää myös

Viite: 2460/101

Tuotemerkki: Narda Safety Test Solutions

Electro and magnetic field meter FieldMan

(0)
The electromagnetic field meter and successor of the NBM series ranging from 0 Hz to 90 GHz. Narda has opened up new dimensions in the versatility and handling of electromagnetic field measuring devices with the FieldMan. This light, easy to use instrument can be operated with various probes (also NBM-probes) to provide reliable, omnidirectional...